SolidSpec-3700i/3700iDUV Spectrophotometer - Options
UV-VIS-NIR Spectrophotometers
Software: LabSolutions UV-Vis
The new spectrophotometer with the LabSolutions UV-Vis software which achieves labor-saving measurement provide a more convenient analytical environment.
Easy-to-use LabSolutions UV-Vis software is included as standard.
UV Accessories & Options
LabSolutions Series
UV-Vis-NIR Spectroscopy Software
-
Shimadzu UV-Vis makes your work faster and easier.
- Simple Easy to use for everyone
- Smart Optimize quality control
- Seamless Easy transfer of measurement data
Related information
-
Shimadzu UV-Vis makes your work faster and easier.
- Simple Easy to use for everyone
- Smart Optimize quality control
- Seamless Easy transfer of measurement data
-
Multifunctional Software with Multiple Measurement Functions / Enhanced GLP/GMP Support Functions
-
Shimadzu offers a wide range of accessories for the UV-Vis spectroscopy analysis of liquids in a variety of forms and conditions. Temperature controlled, micro-volume, turbidity
-
Samples are placed in cells for measurements.
-
This is used to measure samples, without diluting them, with an absorbance too high to be measured using a standard square cell with an optical path length of 10 mm.
-
The following accessories are used to measure micro-volume samples.
-
Shimadzu offers a wide range of accessories for the UV-Vis spectroscopy measurements of solids in a variety of forms and conditions. Transmittance, Reflectance, Specular accessories and more.
-
With relative specular reflectance measurement, the reflectance is calculated from the strength ratio after comparing the light reflected from the reference sample with the light reflected from the measurement sample.
-
With absolute specular reflectance measurement, as shown in the figure, a reference sample is not used, the sample-free state (air) is set at 100%, and the reflection of the sample is simply applied to the 100% setting when measuring the sample.
-
The transmittance of thin samples such as film with little scattering can be measured by combining the film holder with the standard sample compartment.
-
This unit uses a lens and mask to mask the beam that passes through the integrating sphere opening.
-
This software calculates the color values of the measured object from the spectra obtained by the spectrophotometer.
-
This software calculates film thickness from the peak positions of the interference pattern caused by the film.