Upgrade Your Spectral Analysis with IRXross Spectrophotometer

Fourier Transform Infrared Spectrophotometer

User-friendly and versatile Fourier transform infrared (FTIR) spectrophotometer

Fast and sensitive operation for accurate sample analysis

The IRXross™ can analyze a wide range of samples with speed and accuracy. It enables fast, high-resolution measurements, analyzing gases and reactions up to 20 spectra per second.

This model delivers many intuitive features, such as IR Pilot™ – a built-in analytical intelligence feature. With IR Pilot, you can run multiple different analyses with one click. The many pre-built, macro application programs can run many tests, including contaminant analysis, identification testing and pre-shipment inspections. Because of its versatility, the IRXross is ideal for many chemical and pharmaceutical applications.


Key Features

Key features of the IRXross FTIR Spectrophotometer
  • Ultra-high-sensitivity measurements
  • Low noise for more accurate data
  • Rapid Scan option for fast reactions
  • MCT kit option for enhancing sensitivity
  • Spectral library for analyzing contaminants and microplastics
  • Security features that comply with regulations

Quick Specs


Wavenumber Range
7,800 to 350 cm−1

Resolution Range
0.25, 0.5, 1, 2, 4, 8, 16 cm−1

Beam Splitter Type
Germanium-coated KBr

Detector Type
DLATGS detector with temperature control
MCT detector (Hg–Cd–Te) with liquid nitrogen cooling (option)

 

Built-in IR Pilot analytical intelligence feature simplifies operation

  • Intuitive navigation ensures anyone can easily get started

    The IR Pilot™ is an advanced analytical intelligence platform that Includes 23 macro application programs to simply analysis. To get started, simply choose the type of analysis and the attachment. The program will then analyze your sample and generate a report. You can use the program to analyze multiple samples at once, saving time during testing.

    When testing for contaminants, you do not need to specify the mixture’s components. Instead, IR Pilot will identify the components using a spectral library. This feature enables new users to easily analyze contaminants and collect accurate data.

    Learn more about the IR Pilot Identification Test Program

  • Built-in IR Pilot analytical intelligence feature simplifies operation

Microscope accessories support many applications

  • Microscope accessories support many applications
  • AIRsight microscope enhances molecular analysis

    With the AIRsight infrared Raman microscope, you can double your molecular analysis capabilities. This instrument can measure both infrared and Raman spectra from one position. As a result, There is no need to move the sample during your analysis.

    The AIRsight also has powerful 532 nm and 785 nm lasers that can analyze fluorescent samples. This versatility makes the AIRsight microscope suitable for many different applications. 


Complies with data integrity and pharmacopoeia requirements

  • Resist humidity and ensure the reliability of data

    You can select either a KBr or KRS-5 window for your IRXross. The KRS-5 window maintains humidity resistance up to 90 %RH (for temperatures up to 30 °C) and is compliant with pharmacopoeia wavenumber range requirements (350 to 7,800 cm-1).

    LabSolutions™ DB IR and CS IR software also complies with electronic records and electronic signatures (ER/ES) requirements. LabSolutions DB IR is configured with a PC, improving security for facilities that do not require network connections. LabSolutions CS stores data on a server, which can be read by personal computers on the network. This software is a good choice for facilities with large databases that Need to be ER/ES compliant.

  • Complies with data integrity and pharmacopoeia requirements

Videos

Read more
Show Less
Learn More
{"title":"Downloads","description":"Download the latest brochure.","source":"product","key":4657,"max":30,"filter_types":["brochures"],"link_title":"View other Downloads","link_url":"","pdf_links":[]} {"title":"Applications","source":"product","key":4657,"max":3,"filter_types":["applications","application_note","posters"],"link_title":"Learn more","link_url":"\/products\/ftir\/ftir-spectroscopy\/irxross\/applications.html","config_list":[],"page_links":[],"column_title":"Documents"} {"title":"Technical Documents","source":"product","key":4657,"max":3,"filter_types":["technical","technical_reports","white_papers","primers"],"link_title":"Learn more","link_url":"\/products\/ftir\/ftir-spectroscopy\/irxross\/applications.html#tbaleAnchor_technical","config_list":[],"page_links":[],"column_title":"Documents"} {"title":"Manuals","source":"product","key":4657,"max":3,"filter_types":["manuals"],"link_title":"Learn more","link_url":"\/products\/ftir\/ftir-spectroscopy\/irxross\/applications.html#tbaleAnchor_manual","config_list":[],"page_links":[],"column_title":"Documents"}

News / Events

Learn more

Sustainability initiatives