ICPMS-2030
Inductively Coupled Plasma Mass Spectrometer
With its newly developed collision cell and optimized internal structure, the ICPMS-2030 provides superior sensitivity. At the same time, thanks to the adoption of its proprietary mini-torch unit and provision of an Eco mode, the quantity of argon gas needed for analyses has been greatly reduced to the industry's lowest levels. As a result, low running costs are assured. The Development Assistant function of the software automatically sets the optimal analysis conditions for quantitative analysis. Then, after measurements are complete, the Diagnosis Assistant function automatically checks the validity of the necessary data. While reducing the burden on the user, the efficiency of analyses is enhanced and the reliability of the data can be increased. It complies with FDA 21 CFR Part 11.
Features
-
The Development Assistant simplifies the process of developing analytical methods. The Diagnosis Assistant automatically diagnoses spectral interference. Together, they provide analytical results with exceptionally high reliability.
-
Achieve High-Sensitivity and Low-interference Analyses Using Newly Developed Collision Cell
-
Unique Combination Eco Mode/Mini-Torch Reduces Running Cost by Dramatically Reducing Gas ConsumptionIn addition to lower running costs, the environmentally-friendly mini-torch plasma unit, developed by Shimadzu, minimizes the energy (electricity) ...
-
By combining this software with ICPMS-2030 connected to a laser ablation instrument, sample measurement and data output in a format compatible with imaging data analysis software are possible.
Videos
-
ICPMS-2030 Inductively Coupled Plasma Mass Spectrometer
Featuring unique analysis assistant functions and incorporating proprietary cost-reducing capabilities, the ICPMS-2030 provides efficient, sensitive trace element analysis for applications in multiple industries. These include environmental testing, food and agriculture studies, cannabis testing, and pharmaceutical work for analysis of toxic elements according to USP regulations. Simplify your ICP-MS analysis, and obtain reliable trace-level results with confidence.
-
ICPMS 2030 Inductively Coupled Plasma Mass Spectrometer
-
How to Clean ICP-MS Glassware and Cones
Shimadzu's ICP-MS is a robust system that only requires minor routine inspection and cleaning. With ICP-MS systems, all glassware and interface cones should be regularly inspected and cleaned if needed. In addition, the cleaning frequency of the instrument varies by sample matrices and workload. In this video, we will show how to clean and maintain the glassware and cones of Shimadzu’s ICP-MS instrument.
-
ICPMS 2030 Inductively Coupled Plasma Mass Spectrometer
-
Webinar - Applications of ICP-MS in Bioanalysis and the Life Sciences
-
Trace Metals Analysis in Cannabis Products - Tips and Tricks for the ICPMS-2030
-
How to Troubleshoot Low Signal on the ICPMS-2030
One of the most common issues in ICPMS measurements is low signal. This video will provide tips on how to troubleshoot this issue.
News / Events
-
Denver X-ray Conference
August 6-8
Westin Westminster Hotel
Booth #15
Westminster, Colorado -
PITTCON 2024
February 26-28
San Diego Convention Center
San Diego, California
Booth # 2523 -
Shimadzu’s New Inductively Coupled Plasma Mass Spectrometer Series Provides High-Performance Eco-Friendly Elemental Analysis
-
Winter Conference on Plasma Spectrochemistry 2024
January 15-18
El Conquistador Tuscon a Hilton Resort
Tucson, Arizona
-
Shimadzu’s New Atomic Absorption Spectrophotometers Provide Safe High-Performance, High-Sensitivity Analysis
-
Achieve High-Speed, High-Resolution Detection with Shimadzu’s New EDX-7200 Energy Dispersive X-ray Fluorescence Spectrometer