HITS-X Series - Specs
High-Speed Impact Testing Machines
High Speed Tensile Testing Machine HITS-TX
Main Unit, Controller and Software
Product Number |
346-72545 |
---|---|
Impact Test Force |
10 kN |
Maximum Speed |
20 m/s |
Range Of Speed Settings |
0.0001 m/s to 20 m/s*1 |
Piston stroke |
300 mm |
Force Amplifier |
Range: 20%, 50% or 100% of load detector rating / Accuracy: Within 1.0% of full scale Response frequency: DC- 100 kHz (-3 dB) |
Displacement Amplifier |
Range: 10%, 20%, 50% or 100% of 150 mm / Accuracy: Within 1.0% of full scale Response frequency: DC- 10 kHz (-3 dB) |
AD Converter |
Sampling rate: Max. 2 MHz with 12-bit resolution |
Acceleration Jig |
Tapered acceleration mechanism |
Hydraulic Pressure Supply |
Model AF-7H, 7 L /min, air cooled, installed below main unit |
Safety Devices |
Door open/close interlock switch Safety mat interlock switch Two-switch start operation Start timer, etc. |
Controller |
Model 4870 controller (specialized for high-speed impact testing) |
Software |
High-speed impact testing software |
PC Environment Required for Operation*2 |
Compatible OS: Windows 10 (Japanese, English) / Memory capacity: 4 GB or more / |
Power Supply Requirements |
200 V 3-phase 6 kVA, 100 V single-phase 1.5 kVA |
Air Supply Requirements |
Not required |
Dimensions (Main Testing Unit) |
Approx. W1,100 × D700 × H2,850 mm |
Weight (Main Testing Unit) |
Approx. 1,500 kg |
*1: Duration of one test must be within five minutes.
*2: The computer and operating system are not included in the standard system configuration. Please acquire them separately.
High Speed Puncture Impact Testing Machine HITS-PX
Main Unit, Controller and Software
Product Number |
346-72457 |
---|---|
Impact Test Force |
10 kN |
Maximum Speed |
20 m/s |
Range Of Speed Settings |
1 m/s to 20 m/s |
Piston stroke |
300 mm |
Force Amplifier |
Range: 20%, 50% or 100% of load detector rating / Accuracy: Within 1.0% of full scale Response frequency: DC- 100 kHz (-3 dB) |
Displacement Amplifier |
Range: 10%, 20%, 50% or 100% of 150 mm / Accuracy: Within 1.0% of full scale Response frequency: DC- 10 kHz (-3 dB) |
AD Converter |
Sampling rate: Max. 2 MHz with 12-bit resolution |
Specimen Holder |
Pneumtic clamping |
Hydraulic Pressure Supply |
Model AF-7H, 7 L /min, air cooled, installed below main unit |
Safety Devices |
Door open/close interlock switch Safety mat interlock switch Two-switch start operation Start timer, etc. |
Controller |
Model 4870 controller (specialized for high-speed impact testing) |
Software |
High-speed impact testing software |
PC Environment Required for Operation*2 |
Compatible OS: Windows 10 (Japanese, English) / Memory capacity: 4 GB or more / |
Power Supply Requirements |
200 V 3-phase 6 kVA, 100 V single-phase 1.5 kVA |
Air Supply Requirements |
0.6 to 0.7 Mpa |
Dimensions (Main Testing Unit) |
Approx. W1,100 × D900 × H2850 mm |
Weight (Main Testing Unit) |
Approx. 1,500 kg |
HITS-X Series
Impact Test Force |
10 kN |
---|---|
Speed setting range |
1 to 20 m/s |
Piston stroke |
300 mm |
Controller |
Controller 4870 (dedicated controller for high-speed impact testing) |
Software |
TRAPEZIUM HITS high-speed impact testing software |