CLAM-2040 - Options

Fully Automated Sample Preparation Module for LCMS

Specialized Pretreatment Vials

CLAM-2040 uses specialized filter vials for biological sample pretreatment. The single-use ensures the absence of cross-contamination between samples.

Specialized Pretreatment Vials
P/N Description
241-16593-41 Vial Set (set of 100 pairs)
241-16593-42 Vial Set (set of 500 pairs)
241-16593-43 Vial Set (set of 2,000 pairs)
Vial Material Polypropylene (PP)
Filter Material PTFE, with 0.45 μm pore size
Reusability None (disposable)

Sample Vials

Sample Vials

CLAM-2040 is compatible with any sampling tubes of 13 mm diameter and 75 mm height.

Examples: BD brand Vacutainer® blood collection tubes, Terumo brand VENOJECT® II blood collection tubes, Nipro brand Neotube blood collection tubes.

  Appearance P/N Quantity
3 mL Cup
3 mL Cup
038-00531-01 1000 cups/pk
Micro-Volume Cup
Micro-Volume Cup
241-94045-01 1000 cups/pk
Cap-on 1.5 mL Tube
Cap-on 1.5 mL Tube
038-00051-68 1 tube/pk
Cap-on Test Tube
Cap-on Test Tube
046-00342-01 1 tube/pk

 

Reagent Vials

CLAM-2040 uses reagent vials of 3 different volumes, for maximum adaptability and flexibility : 1.5mL, 6mL or 12mL.

  Appearance P/N Description Quantity
1.5 mL Vial
1.5 mL Vial
228-16965-91 Vial 100 vials/pk
241-18511-41 Septum sets for 1.5 mL vial
• Caps • Septum
• Filter paper
100 sets/pk
6 mL Vial
6 mL Vial
241-16619-43 Vial 50 vials/pk
241-18512-41 Septum sets for 6 mL vial
• Septum
• Filter paper
50 sets/pk
038-00199-33 Cap, 6 mL 1 cap/pk
12 mL Vial
12 mL Vial
223-81340-41 Vial 1 vial/pk
223-81468-02 Septum to Prevent Absorbing Humidity
1 septum/pk
1 septum/pk
038-00199-34 Cap, 12 mL 1 cap/pk

Software Options

Optimized methods can be provided, so that there is no need for the user to do complicated development work, such as examining the HPLC separation conditions or optimizing MS parameters for each compound. Method files are provided ready to use.

LC/MS/MS Rapid Toxicology Screening System

LC/MS/MS Rapid Toxicology Screening System

This product includes methods for simultaneous or individual analysis of 235 components, including drug of abuse, psychiatric and neurological drugs, and hypnotics and sedatives.

 

In addition, the Synchronized Survey Scan™ function provides optimized conditions for screening measurements (product ion spectrum acquisition conditions with threshold intensity in MRM).

 

LC/MS/MS Forensic Toxicological Database

LC/MS/MS Forensic Toxicological Database

This database includes information on drugs of abuse, hypnotics, psychotropics, pesticides, prescription drugs and natural toxins.

MRM & Spectral Library database for more than 7,000 compounds

The spectral library database is built using two HPLC separations. Both methods have information on clinical and forensic compounds of interest in routine analysis. This product provides Synchronized Survey Scan parameters (MRM parameters, MRM intensity threshold and triggered product ion scan parameters) optimized for screening analysis. In addition, a data sheet describing the monoisotopic mass, chemical formula, CAS number, etc. of the registered compound is included, making it easy to search for the medicinal and toxicant you want to measure.

Enhanced identification by merged spectrum

Each certified reference material was acquired with three different collision energies to generate an information-rich merged-CE spectrum which can be used in library matching and compound verification. Matching with a merged-CE spectrum library is a powerful tool to identify compounds with higher confidence.

 

 

Application Specific LC-MS Systems