PPSQ-51A/53A
Protein Sequencer
The PPSQ is an instrument for determining the amino acid sequences of proteins and peptides, which combines an Edman reaction section with a high performance liquid chromatograph (HPLC). There are 2 types: the PPSQ-51A, which is equipped with one reactor, and the PPSQ-53A, which is equipped with three reactors. On the PPSQ-53A, the continuous analysis of the amino acid sequences of multiple samples can be performed one after another. In the Edman reaction section, amino acids are cleaved in order from the N-terminal of a protein by repeatedly performing Edman degradation, and are derivatized. As a result, stable PTH-amino acids are produced. The PTH-amino acids are injected online into the HPLC, and analysis is performed. The HPLC data is saved on the PC, and data processing software is used to process the chromatograms. Then, amino acid sequence estimation software is used to identify the amino acids and estimate the sequences.
Benefits of using Edman degradation for amino acid sequencing:
(1) Guaranteed N-terminal sequence of proteins
(2) No sample pre-treatment required
(3) Differentiation of isobaric amino acids (leucine and isoleucine)
(4) Identification possible even from unknown proteins not registered in databases
Features
-
LabSolutions PPSQ software provides compliance with FDA 21 CFR Part 11 guidelines and enables compliance with the security, user management, and audit trail requirements specified by FDA 21 CFR Part 11....
-
Baseline Stability
PPSQ series protein sequencers separate PTH-amino acids isocratically. This improves baseline stability and allows high ...
-
High-Sensitivity Analysis
A high-sensitivity flow cell enables high-sensitivity detection of PTH-amino acids, which allows for sequential analysis using trace samples...
Videos
-
Calibrating and Automated Edman Degradation System (PPSQ)
This video demonstrates how to load, run and calibrate an Automated Edman Degradation (PPSQ) system using a PTH-Amino Acid standard.
-
Running Apomyoglobin on an Automated Edman Degradation System (PPSQ)
This video demonstrates how to run Apomyoglobin, our protein standard, on our Automated Edman Degradation (PPSQ) system.
News / Events
-
US HUPO One World (Human Proteome Organization) Conference
February 22-25
Philadelphia Lowes Hotel
Philadelphia, PA -
Shimadzu Introduces iMScope™ QT Imaging Mass Microscope for High-Level Mass Spectrometry Imaging Analysis
Shimadzu Scientific Instruments introduces the iMScope QT imaging mass microscope designed for use with Shimadzu’s Q-TOF LCMS-9030mass spectrometer for fast acquisition of high-mass, high-resolution images at the optical and molecular level. When paired with the Q-TOF LCMS-9030, the iMScope QT provides a complete, high-end analytical solution combining precise tools and data processing that is unrivalled in the marketplace.