DUH-210/DUH-210S Dynamic Ultra Micro Hardness Tester - Specs
Dynamic Ultra Micro Hardness Tester
DUH-211
P/N |
344-04250-XX (Windows 10) |
---|---|
Required PC Specifications : OS |
PCI Express ×1 (full-length), 2 slots min. more than one ×1 slot is reguired (or slot size ×2 or more) |
Specimen Stage : Vertical Distance |
Approx. 60 mm |
Specimen Stage : Area |
Approx. 125 (W) × 125 (L) mm |
Specimen Stage : Stage Movement Range |
25 mm in both X and Y directions |
Specimen Stage : Specimen Holder |
Specimen dimensions (i.e., 8 (thickness) × 30 (width) mm) when thin-type attachment (type 3) is used |
Required PC Specifications : OS |
Windows® 10 Pro (64 bit edition) |
Required PC Specifications : OS |
CD-ROM drive |
Utilities : Power Supply |
Single phase, AC 100–115 V ± 10%, AC 230 V ± 10% (Ground resistance 100 Ω max.) |
Micrometer : Effective Measurement Range |
200 µm (with ×50 objective lens) |
Utilities : Power Consumption |
Approx. 100 W (not including power consumption of PC) |
Utilities : Grounding |
The ground terminal on 3-prong connectors must be properly grounded with grounding resistance at 100 Ω or less. |
Utilities : Temperature |
Recommended temperature: 23±1°C,Allowable range: 10°C to 35°C |
Utilities : Vibration |
Horizontal vibration: 0.017 Gal max. (at 10 Hz or more), 0.01 µm max. (at less than 10 Hz),Vertical vibration: 0.010 Gal max. (at 10 Hz or more), 0.005 µm max. (at less than 10 Hz) |
Utilities : Humidity |
80% max. (no condensation) |
External Dimensions |
Tester: Approx. 355 (W) × 405 (D) × 530 (H) mm |
Micrometer : Minimum Measurement Increment |
0.01 µm/pulse |
Micrometer : Detector |
Optical encoder |
Loading Unit : Loading Method |
Electromagnetic coil |
Displacement Measurement Unit : Measurement Method |
±2% of full scale (20 µm) |
Loading Unit : Test Force Range |
Full scale of 0.1 to 1,961 mN |
Loading Unit : Test Force Accuracy |
±19.6 µN or ±1% of displayed test force, whichever is greater |
Loading Unit : Minimum Measurement Increment |
0.196 µN (for a test force not exceeding 1.96 mN) |
Displacement Measurement Unit : Measurement Method |
Differential transformer |
Displacement Measurement Unit : Measurement Method |
0 to 10 µm |
Displacement Measurement Unit : Measurement Method |
0.0001 µm |
Indenter : Type |
Triangular pyramid indenter with tip angle of 115° (Vickers indenter and Knoop indenter are available as options.) |
Micrometer : Collimation Method |
Direct connection between encoder and control handle; synchronized movement of two indexes |
Indenter : Tip Radius |
0.1 µm max. |
Optical monitor : Total magnification |
×500 |
Optical Monitor : Objective Lens |
×50 (Up to 2 lenses can be attached.) |
Optical Monitor : Eyepiece |
×10 |
Optical Monitor : Lighting Method |
Reflected illumination |
Optical Monitor : Light Source (lamp) |
LED: 3 W, 3 V |
Optical Monitor : Light-Path Switching |
Observation or photograph (selectable) |
Weight |
Tester: Approx. 60 kg |
DUH-211S
P/N |
344-04251-XX (Windows 10) |
---|---|
Required PC Specifications : OS |
PCI Express ×1 (full-length), 2 slots min. more than one ×1 slot is reguired (or slot size ×2 or more) |
Specimen Stage : Vertical Distance |
Approx. 60 mm |
Specimen Stage : Area |
Approx. 125 (W) × 125 (L) mm |
Specimen Stage : Stage Movement Range |
25 mm in both X and Y directions |
Specimen Stage : Specimen Holder |
Specimen dimensions (i.e., 8 (thickness) × 30 (width) mm) when thin-type attachment (type 3) is used |
Required PC Specifications : OS |
Windows® 10 Pro (64 bit edition) |
Required PC Specifications : OS |
CD-ROM drive |
Utilities : Power Supply |
Single phase, AC 100–115 V ± 10%, AC 230 V ± 10% (Ground resistance 100 Ω max.) |
Micrometer : Effective Measurement Range |
200 µm (with ×50 objective lens) |
Utilities : Power Consumption |
Approx. 100 W (not including power consumption of PC) |
Utilities : Grounding |
The ground terminal on 3-prong connectors must be properly grounded with grounding resistance at 100 Ω or less. |
Utilities : Temperature |
Recommended temperature: 23±1°C,Allowable range: 10°C to 35°C |
Utilities : Vibration |
Horizontal vibration: 0.017 Gal max. (at 10 Hz or more), 0.01 µm max. (at less than 10 Hz),Vertical vibration: 0.010 Gal max. (at 10 Hz or more), 0.005 µm max. (at less than 10 Hz) |
Utilities : Humidity |
80% max. (no condensation) |
External Dimensions |
Tester: Approx. 355 (W) × 405 (D) × 530 (H) mm |
Micrometer : Minimum Measurement Increment |
0.01 µm/pulse |
Micrometer : Detector |
Optical encoder |
Loading Unit : Loading Method |
Electromagnetic coil |
Displacement Measurement Unit : Measurement Method |
±2% of full scale (20 µm) |
Loading Unit : Test Force Range |
Full scale of 0.1 to 1,961 mN |
Loading Unit : Test Force Accuracy |
±19.6 µN or ±1% of displayed test force, whichever is greater |
Loading Unit : Minimum Measurement Increment |
0.196 µN (for a test force not exceeding 1.96 mN) |
Displacement Measurement Unit : Measurement Method |
Differential transformer |
Displacement Measurement Unit : Measurement Method |
0 to 10 µm |
Displacement Measurement Unit : Measurement Method |
0.0001 µm |
Indenter : Type |
Triangular pyramid indenter with tip angle of 115° (Vickers indenter and Knoop indenter are available as options.) |
Micrometer : Collimation Method |
Direct connection between encoder and control handle; synchronized movement of two indexes |
Indenter : Tip Radius |
0.1 µm max. |
Optical monitor : Total magnification |
×500 |
Optical Monitor : Objective Lens |
×50 (Up to 2 lenses can be attached.) |
Optical Monitor : Eyepiece |
×10 |
Optical Monitor : Lighting Method |
Reflected illumination |
Optical Monitor : Light Source (lamp) |
LED: 3 W, 3 V |
Optical Monitor : Light-Path Switching |
Observation or photograph (selectable) |
Weight |
Tester: Approx. 60 kg |
DUH-211
Test force range |
0.1 to 1,961 mN (0.01 to 200 gf) |
---|---|
Indentation depth range |
0 to 10 µm |
Minimum display |
0.0001 µm |
Testing mode |
3 types (211 model), 7 types (211S model) |
DUH-211S
Test force range |
0.1 to 1,961 mN (0.01 to 200 gf) |
---|---|
Indentation depth range |
0 to 10 µm |
Minimum display |
0.0001 µm |
Testing mode |
3 types (211 model), 7 types (211S model) |