EHF-E Series - Specs
Servopulser Fatigue and Endurance Testing Machine
EHF-EV051k2
Max. dynamic test force |
±50kN |
---|---|
Max. static test force |
±60kN |
Actuator stroke |
±50mm |
Cycle speed and amplitude |
See amplitude characteristics charts. |
Controlled items |
Test force and stroke (two can be added as options) |
Test force : Range |
24-bit rangeless |
Test force : Indication accuracy |
Within 0.5 % of indicated value or ±0.02 % of maximum dynamic test force, whichever is greater |
Crosshead drive mechanism |
Hydraulic drive (with hydraulic clamp) |
Applicable hydraulic power supply unit |
QF-10B, QF-20B, QF-40B, QF-70B, QF-110, QF-140 |
Power Requirements |
Varies depending on the hydraulic power supply unit (see pages 34 and 35). |
EHF-EV101k1
Max. dynamic test force |
±100kN |
---|---|
Max. static test force |
±120kN |
Actuator stroke |
±25mm |
Cycle speed and amplitude |
See amplitude characteristics charts. |
Controlled items |
Test force and stroke (two can be added as options) |
Test force : Range |
24-bit rangeless |
Test force : Indication accuracy |
Within 0.5 % of indicated value or ±0.02 % of maximum dynamic test force, whichever is greater |
Crosshead drive mechanism |
Hydraulic drive (with hydraulic clamp) |
Applicable hydraulic power supply unit |
QF-10B, QF-20B, QF-40B, QF-70B, QF-110, QF-140 |
Power Requirements |
Varies depending on the hydraulic power supply unit (see pages 34 and 35). |
EHF-EV051k1
Max. dynamic test force |
±50kN |
---|---|
Max. static test force |
±60kN |
Actuator stroke |
±25mm |
Cycle speed and amplitude |
See amplitude characteristics charts. |
Controlled items |
Test force and stroke (two can be added as options) |
Test force : Range |
24-bit rangeless |
Test force : Indication accuracy |
Within 0.5 % of indicated value or ±0.02 % of maximum dynamic test force, whichever is greater |
Crosshead drive mechanism |
Hydraulic drive (with hydraulic clamp) |
Applicable hydraulic power supply unit |
QF-10B, QF-20B, QF-40B, QF-70B, QF-110, QF-140 |
Power Requirements |
Varies depending on the hydraulic power supply unit (see pages 34 and 35). |
EHF-EV101k2
Max. dynamic test force |
±100kN |
---|---|
Max. static test force |
±120kN |
Actuator stroke |
±50mm |
Cycle speed and amplitude |
See amplitude characteristics charts. |
Controlled items |
Test force and stroke (two can be added as options) |
Test force : Range |
24-bit rangeless |
Test force : Indication accuracy |
Within 0.5 % of indicated value or ±0.02 % of maximum dynamic test force, whichever is greater |
Crosshead drive mechanism |
Hydraulic drive (with hydraulic clamp) |
Applicable hydraulic power supply unit |
QF-10B, QF-20B, QF-40B, QF-70B, QF-110, QF-140 |
Power Requirements |
Varies depending on the hydraulic power supply unit (see pages 34 and 35). |
EHF-EV200k1
Max. dynamic test force |
±200kN |
---|---|
Max. static test force |
±240kN |
Actuator stroke |
±25mm |
Cycle speed and amplitude |
See amplitude characteristics charts. |
Controlled items |
Test force and stroke (two can be added as options) |
Test force : Range |
24-bit rangeless |
Test force : Indication accuracy |
Within 0.5 % of indicated value or ±0.02 % of maximum dynamic test force, whichever is greater |
Crosshead drive mechanism |
Hydraulic drive (with hydraulic clamp) |
Applicable hydraulic power supply unit |
QF-10B, QF-20B, QF-40B, QF-70B, QF-110, QF-140 |
Power Requirements |
Varies depending on the hydraulic power supply unit (see pages 34 and 35). |
EHF-EV200k2
Max. dynamic test force |
±200kN |
---|---|
Max. static test force |
±240kN |
Actuator stroke |
±50mm |
Cycle speed and amplitude |
See amplitude characteristics charts. |
Controlled items |
Test force and stroke (two can be added as options) |
Test force : Range |
24-bit rangeless |
Test force : Indication accuracy |
Within 0.5 % of indicated value or ±0.02 % of maximum dynamic test force, whichever is greater |
Crosshead drive mechanism |
Hydraulic drive (with hydraulic clamp) |
Applicable hydraulic power supply unit |
QF-10B, QF-20B, QF-40B, QF-70B, QF-110, QF-140 |
Power Requirements |
Varies depending on the hydraulic power supply unit (see pages 34 and 35). |