LabSolutions™ ICPMS Ver. 2 Software
ICPMS Software
The new version of LabSolutions ICPMS software displays all necessary information in a single window, simplifying operation for new users. Experienced users can utilize advanced configurable settings for challenging applications, in-depth research and all analyses in between.
-
Analysis Window
The customizable analysis window can simultaneously display the current sample profile, registered samples, analytical results, errors, and instrument status. The analysis progress can be monitored at a glance. Windows can be configured and customized based on the user's preference. The assistant bar along the left side guides the users through every step of analysis in the correct order.
-
-
Instrument Status Window
The instrument status window displays various information about the instrument and accessories in a comprehensive and easy-to-understand layout. A warning indicator is displayed if an error occurs or if a part is due for maintenance or replacement.
-
-
Automatic Internal Standard Monitoring
Internal standard fluctuation can be displayed as a graph for the entire analysis time, as either intensity or intensity ratio with respect to a reference sample. This helps quickly identify complications that occur due to sample matrix effects.
-
-
Simple and Descriptive
Maintenance WindowThe maintenance information/setting window in new LabSolutions™ ICPMS software clearly indicates operation times of key components and automatically alerts users when it is time to maintain and/or replace parts, taking the guesswork out of maintenance.
-
-
LabSolutions ICPMS TRM (Optional)
Shimadzu LC-ICP-MS systems combined with LabSolutions ICPMS TRM software can be used to speciate arsenic, mercury, and other elements. The software controls and configures both LC and ICPMS systems in one simple platform.
-
LabSolutions™ CS Supports Laboratory Networking
Adding a LabSolutions™ DB/CS connection kit (optional) enables compliance with electronic recordkeeping and electronic signature regulations, such as requirements specified in FDA 21 CFR Part 11. Select either a standalone (LabSolutions DB) or networked (LabSolutions CS) system that is best for the given application. LabSolutions CS manages all analytical data in a database on a network server, so that the data can be loaded and postrun analysis can be performed on any computer connected to the network.
Note: An additional software license is required for loading data onto a computer not connected to an ICPMS-2040/2050 Series system.
*1 The acquisition control PC controls analytical instruments. It can also be used to send analytical instructions and perform postrun analysis, just like a client PC.
*2 If a terminal service is used, then LabSolutions software does not need to be installed on client PCs.
*3 If an iPad is used, then XenApp from Citrix must be installed.
News / Events
-
Denver X-ray Conference
August 6-8
Westin Westminster Hotel
Booth #15
Westminster, Colorado -
PITTCON 2024
February 26-28
San Diego Convention Center
San Diego, California
Booth # 2523 -
Shimadzu’s New Inductively Coupled Plasma Mass Spectrometer Series Provides High-Performance Eco-Friendly Elemental Analysis
-
Winter Conference on Plasma Spectrochemistry 2024
January 15-18
El Conquistador Tuscon a Hilton Resort
Tucson, Arizona
-
Shimadzu’s New Atomic Absorption Spectrophotometers Provide Safe High-Performance, High-Sensitivity Analysis
-
Achieve High-Speed, High-Resolution Detection with Shimadzu’s New EDX-7200 Energy Dispersive X-ray Fluorescence Spectrometer