AT Series - Specs
Analytical Balaneces
ATX124
Capacity |
120 g |
---|---|
Minimum display |
0.1 mg |
Repeatability (Standard deviation) |
≤0.1 mg |
Linearity |
±0.2 mg |
Stabilisation Time*1 |
Approx. 3.0 seconds |
Operating Temperature and Humidity |
5-40°C 20-85%*2 |
Temperature Coefficient for Sensitivity (10-30°C) |
±2ppm/°C |
Pan Size (mm) approx. |
Φ91 |
Main Body Dimensions (mm) approx. |
213(W) x 356(D) x 338(H) |
Main Body Weight (kg) approx. |
6.2 |
Power requirement |
12V, 1A |
ATX224
Capacity |
220 g |
---|---|
Minimum display |
0.1 mg |
Repeatability (Standard deviation) |
≤0.1 mg |
Linearity |
±0.2 mg |
Stabilisation Time*1 |
Approx. 3.0 seconds |
Operating Temperature and Humidity |
5-40°C 20-85%*2 |
Temperature Coefficient for Sensitivity (10-30°C) |
±2ppm/°C |
Pan Size (mm) approx. |
Φ91 |
Main Body Dimensions (mm) approx. |
213(W) x 356(D) x 338(H) |
Main Body Weight (kg) approx. |
6.2 |
Power requirement |
12V, 1A |
ATX324
Capacity |
320 g |
---|---|
Minimum display |
0.1 mg |
Repeatability (Standard deviation) |
≤0.1 mg |
Linearity |
±0.2 mg |
Stabilisation Time*1 |
Approx. 3.0 seconds |
Operating Temperature and Humidity |
5-40°C 20-85%*2 |
Temperature Coefficient for Sensitivity (10-30°C) |
±2ppm/°C |
Pan Size (mm) approx. |
Φ91 |
Main Body Dimensions (mm) approx. |
213(W) x 356(D) x 338(H) |
Main Body Weight (kg) approx. |
6.2 |
Power requirement |
12V, 1A |
ATY64
Capacity |
62 g |
---|---|
Minimum display |
0.1 mg |
Repeatability (Standard deviation) |
≤0.1 mg |
Linearity |
±0.2 mg |
Stabilisation Time*1 |
Approx. 3.0 seconds |
Operating Temperature and Humidity |
5-40°C 20-85%*2 |
Temperature Coefficient for Sensitivity (10-30°C) |
±2ppm/°C |
Pan Size (mm) approx. |
Φ91 |
Main Body Dimensions (mm) approx. |
213(W) x 356(D) x 338(H) |
Main Body Weight (kg) approx. |
6.0 |
Power requirement |
12V, 1A |
ATY124
Capacity |
120 g |
---|---|
Minimum display |
0.1 mg |
Repeatability (Standard deviation) |
≤0.1 mg |
Linearity |
±0.2 mg |
Stabilisation Time*1 |
Approx. 3.0 seconds |
Operating Temperature and Humidity |
5-40°C 20-85%*2 |
Temperature Coefficient for Sensitivity (10-30°C) |
±2ppm/°C |
Pan Size (mm) approx. |
Φ91 |
Main Body Dimensions (mm) approx. |
213(W) x 356(D) x 338(H) |
Main Body Weight (kg) approx. |
6.0 |
Power requirement |
12V, 1A |
ATY224
Capacity |
220 g |
---|---|
Minimum display |
0.1 mg |
Repeatability (Standard deviation) |
≤0.1 mg |
Linearity |
±0.2 mg |
Stabilisation Time*1 |
Approx. 3.0 seconds |
Operating Temperature and Humidity |
5-40°C 20-85%*2 |
Temperature Coefficient for Sensitivity (10-30°C) |
±2ppm/°C |
Pan Size (mm) approx. |
Φ91 |
Main Body Dimensions (mm) approx. |
213(W) x 356(D) x 338(H) |
Main Body Weight (kg) approx. |
6.0 |
Power requirement |
12V, 1A |
ATY324
Capacity |
320 g |
---|---|
Minimum display |
0.1 mg |
Repeatability (Standard deviation) |
≤0.1 mg |
Linearity |
±0.2 mg |
Stabilisation Time*1 |
Approx. 3.0 seconds |
Operating Temperature and Humidity |
5-40°C 20-85%*2 |
Temperature Coefficient for Sensitivity (10-30°C) |
±2ppm/°C |
Pan Size (mm) approx. |
Φ91 |
Main Body Dimensions (mm) approx. |
213(W) x 356(D) x 338(H) |
Main Body Weight (kg) approx. |
6.0 |
Power requirement |
12V, 1A |
ATX84
Capacity |
82 g |
---|---|
Minimum display |
0.1 mg |
Repeatability (Standard deviation) |
≤0.1 mg |
Linearity |
±0.2 mg |
Stabilisation Time*1 |
Approx. 3.0 seconds |
Operating Temperature and Humidity |
5-40°C 20-85%*2 |
Temperature Coefficient for Sensitivity (10-30°C) |
±2ppm/°C |
Pan Size (mm) approx. |
Φ91 |
Main Body Dimensions (mm) approx. |
213(W) x 356(D) x 338(H) |
Main Body Weight (kg) approx. |
6.2 |
Power requirement |
12V, 1A |
*1 The Stabilisation time is a representative value