Constant-Temperature Measurement


Example of Measurement of Serum Cholinesterase Activity
The following accessories are used for biological component measurement, enzymatic activity measurement and reaction rate analysis for which the sample must be kept at a constant temperature. The figure shows an example in which enzymatic activities are measured using the CPS-240A cell positioner, 6 cell-thermoelectrical temperature controller. The reactions in the six cells were measured in parallel in a measurement time of 200 seconds.
CPS-240A Cell Positioner,6 Cell-Thermoelectrical Temperature Controller
This accessory automatically switches measurement between the six cells to ensure efficient measurement. Accurate temperature conditions can be maintained without the need for circulation of cooling water.

  • For UVmini series, UV-1800/2450/2550/2600/2700/3600
*) Square cells are not included in the standard package. Please purchase separately.
*) When used on the UV-1800, the CPS USB adapter is required.
TCC-240A Thermoelectrically Temperature Controlled Cell Holder
This easy-to-use cell holder uses a Peltier element to electronically control the temperature, so no external thermostatic bath or cooling water circulation is required.

  • For UVmini series, UV-1800/2450/2550/2600/2700/3600
*) Square cells are not included in the standard package. Please purchase separately.
*) The stirrer is optional. Please purchase separately.
Constant-Temperature Cell Holder
This holder holds the sample cell at the desired, uniform temperature by circulating constant-temperature water. It accepts a pair of 10 mm square cells.

  • For UVmini series, UV-1800/2450/2550/2600/2700/3600

*) When used on the UVmini series, the sample compartment unit is required.
S-1700 Thermoelectric Single Cell Holder
This cell holder enables setting of the temperature program to raise and lower the sample cell temperature. The thermoelectric system enables the sample temperature to be controlled between 0 and 110 °C. A stirrer is also provided to ensure uniform temperature distribution throughout the cell.

  • For UVmini series, UV-1800/2450/2550/2600/2700/3600
*) Temperature is not controlled on the reference side.
*) Cooling water circulation is required for cooling the Peltier element. Though tap water can be used for cooling, the following conditions must be satisfied to elicit the maximum performance of the instrument. Use of a commercially available constant-temperature water circulator is recommended.

  • Cooling water temperature: 20±2 °C
  • Flow rate: 4.8 L/min or more

*) Cells are not provided. The following 10 mm square cell with a stopper (made by Hellma) is required.
Type Optical Path Length Minimum Required Sample Volume
110-QS-10 10 mm 3.5 mL
115B-QS-10 10 mm 400 µL
NTT-2200PP Constant-Temperature Water Circulator
This accessory circulates temperature-controlled water to a constant-temperature cell holder.
  • Temperature control range: 35 to 80°C
    (ambient +5 to +80°C at room temperature 30°C or more)
  • Temperature control precision: ±0.05°C or more
  • Max. pump circulation rate: 27/31 L/min
  • Max. pump head: 9.5/13 m (50/60 Hz)
  • External circulation nozzle: 10.5 mm O.D. (both outlet and return)
  • Tank capacity: Approx. 10 L (9 L during operation)
  • Standard accessories: Lid with handles, hose 4 m (I.D. 8 mm dia., O.D. 12 mm dia.), 4 hose clamps, Instruction Manual
  • Size: 270W x 560H x 400D (mm)
  • Power requirements: 100 VAC, 1250 VA, with 1.7 m power cable and grounded plug

For Research Use Only. Not for use in diagnostic procedures.