ICPMS-2030 Inductively Coupled Plasma Mass Spectrometer
Accelerating Reliable Performance


Autosampler AS-10
(For automatic analysis of 60 samples)

Autosampler AS-10

Autosampler AS-10

Multiple samples can be analyzed successively. The turntable results in a short path length for sample injection, which can reduce the rinse time.

Vials: 60 15- mL vials
8 50-mL vials
Size: W290 × D508 × H300 mm (excluding arm)
Power supply: Single-phase 100 V, 50/60 Hz, 100 VA
Note: Requires separate power cord (P/N S071-60821-08).
Note: An additional rinsing port is optional (There is no automatic solvent supply).
Rinsing Port Expansion Kit for AS-10.

Autosampler ASX-26
(For simultaneous analysis of 120 samples)

ASX-26 Autosampler

ASX-26 Autosampler

Vials:
10 50-mL vials (standard samples) or 120 14-mL vials
80 20-mL vials (rack sold separately)
42 50-mL vials (rack sold separately)
Size: W330 × D508 × H250 mm
(main unit/excluding sample probe unit)
W90 × D180 × H60 mm
(rough dimensions of power supply unit)
Power supply: 100 V AC ± 10 %, 200 VA, 50/60Hz
Weight: 8.4 kg (main unit)
Note: Requires a separate connection kit.

Autosampler ASX-520
(For simultaneous analysis of 240 samples)

Autosampler ASX-520

Autosampler ASX-520

Vials: 10 50-mL vials (standard samples) or 240 14-mL vials 160 20-mL vials (rack sold separately) 84 50-mL vials (rack sold separately) Size: W520 × D482 × H250 mm (main unit/excluding sample probe unit) W90 × D180 × H60 mm (rough dimensions of power supply unit) Power supply: 100 V AC ± 10 %, 200 VA, 50/60Hz Weight: 10.5 kg (main unit) Note: Requires a separate connection kit (P/N S211-94010-41).

HVG-1 Hydride Generator
For high-sensitivity analysis of As, Se, and Sb

HVG-1 Hydride Generator

HVG-1 Hydride Generator

This unit uses nascent hydrogen generated from decomposition of sodium borohydride to vaporize elements in samples by reduction and then introduce only the gas phase into the plasma. This enables measurements with about 50 times higher sensitivity.
Note: Requires a separate HVG-ICPMS connection kit and liquid waste pump

Cooling Water Circulator Set

Cooling Water Circulator Set

Cooling Water Circulator Set

Size: W377 × D500 × H615 mm
Power supply: Single-phase 200 V, 50/60 Hz, 2 kVA
Weight: 43 kg

Note: Used to cool the main unit.
Note: Requires a separate chiller connection kit (P/N S211-93827-41).
Note: Requires tetoron braided hoses (P/N S018-31509) for coolant water supply and drain. Order in meter units for the overall length.

LC Connection Kit

This kit is used to connect ICPMS to an LC system (Prominence inert LC System).
Note: Requires LabSolutions ICPMS TRM (software) (P/N S211-49200-91) for LC Connection Kit

Automatic Internal Standard Addition Kit

This kit is used for in-line mixing of measurement sample and internal standard solutions and introducing the mixtures into the ICP system.

HFS-5 Hydrofluoric Acid Sample Injection System

This system includes a torch, chamber, extension tube, nebulizer, drain, and their corresponding accessory parts. If purchasing a new system, order this kit and an S2 orifice assembly. Used to directly inject samples that contain hydrofluoric acid. The nebulizer, chamber, and drain system are made using fluoropolymer materials and the injector unit on the torch is made using alumina.

Organic Solvent Injection System

To introduce organic solvents, a mixture of argon and oxygen gases (70% Ar and 30% O2) is injected into the interface unit to prevent precipitation of carbon (C) by the organic solvent. This system includes a Quadruple Torch for Organic Solvents, ICPMS, drain, and their corresponding accessory parts.

Laser Ablation Connection Kit

This connection kit is compatible with ESI NWR-213 laser ablation systems.

Tap Water Connection Kit

This is required if using tap water to cool the main ICPMS-2030 unit. Note: Requires a separate coupler set for tap water connection.

Exhaust Duct Connection Adapter

Noise Reduction Box for Rotary Pumps

Note: Requires Noise Reduction Box Connection Kit for Noise Reduction Box for Rotary Pumps.

For Research Use Only. Not for use in diagnostic procedures.