CTO-20A/20AC
Prominence HPLC Column Ovens


CTO-20A
Large-capacity, forced hot-air circulation units, the CTO-20A/20AC HPLC column ovens precisely regulate the temperature around the column. Automatic fan-speed control varies with the set temperature to provide stable analysis that is not influenced by the ambient temperature.
CTO-20A - Precise Temperature Control
A forced-air circulation-type column oven, the CTO-20A can regulate the temperature from 10ºC above room temperature to 85ºC. Rapid temperature equilibration allows complex temperature programs incorporating linear and/or step-wise increases and decreases in temperature.
CTO-20AC - Column Cooling Supported
The CTO-20AC can heat and cool the column compartment, utilizing a Peltier cooling device to provide sub-ambient conditions. Temperature control is regulated over a wide range, from 10ºC below room temperature to 85ºC, for increased reproducibility and separation performance.

Features

Precise Temperature Regulation
The interior of the oven is precisely regulated with a high-performance thermistor. The temperature is calibrated at two different temperatures to ensure a high level of temperature accuracy.
Large Inner Space
In addition to the column, other system parts can be accommodated. These include:
  • Manual injector
  • Gradient mixer
  • High-pressure flow-line selection valves (2-position/6-port valves or 6-position/7-port valves, two in total)
  • Conductivity-detection cell block
  • Pre-or post-column reaction coil
Column Management Device (CMD)
Both the CTO-20A and 20-AC support the CMD. The CMD provides:
  • Recorded information about column usage
  • Amount of mobile phase delivered
  • Composition of the last mobile phase used
  • Number of samples injected
This information is managed through an LC workstation (with LCsolution) or a PC in the network using the CBM-20A System Controller's Web-control function.
Optional Flow-Line and Column Selection Valves
The FCV-20AH2/20AH6 valves are stand-alone, high-pressure, flow-line or column selection valves. The valve position is controlled by event signal input. Direct control is also possible from the unit itself.

Specifications

CTO-20ACTO-20AC
Temperature-control methodForced-air circulation
Cooling methodNoneElectronic cooling
Temperature-setting range4oC to 85oC
Temperature-control precision0.1oC max.
Temperature-control range10oC above room temperature to 85oC10oC below room temperature to 85oc
Storage capacity10 columns, max 25 cm length
Storable devices2 manual injectors, gradient mixer, 2 high-pressure flow-line selection valves, etc.
Time programLinear temperature programs supported
Safety measuresSolvent sensor, temperature fuse, temperature upper limit
Operating temperature range4oC to 35oC
Dimensions, weight260 (W) x 415 (H) x 420 (D) mm, 20 kg260 (W) x 415 (H) x 420 (D) mm, 23 kg
Power requirements100 VAC, 500 VA, 50/60 Hz